Acteon X-mind DC is an extraoral source of X-rays intended to be used for the generation of intra oral images for the treatment of disease of teeth, jaw and oral structures. This X-ray unit can also be applied in routine dental radiographic examinations which involves the diagnosis, treatment such as, surgical or interventional, of disease of the teeth, jaw and oral cavity structures. X-mind DC intends for medical applications such as, General Dentistry, Dental Implantology and Dental Surgery. X-Mind DC is delivered with a generator 70KV, a pantograph, an extensor and a timer.
The X-Mind DC radiographic system consists of:
X-Mind DC Timer: The timer is the control panel used to safely use the tube head and to manage the exposure times. Control button with safety key exist to make the exposure. The timer can be connected to n degree 2cc tubeheads.
Bracket: It is available in three different lengths (110cm, 80cm, 40cm) and supports the pantograph arm. Its shaft is fixed to a section of the timer and allows 180 degrees movement.
Pantograph Type Arm: Its length can be adjusted to precisely explore any spot in its reach. It is made of light alloy with an ABS coating.
Tubehead: Light alloy housing is separated into two compartments, the x-ray tube and the expansion chamber. Both are submerged in highly dielectric insulating oil inside a light alloy container. The expansion chamber guarantees an adequate compensation to oil expansion for the entire temperature range. The X-ray tube is at the back of the container, allowing a source-skin distance 50% higher than traditional structures. In the second compartment the main electronic board and the control electronic board are placed.
Cone (Collimator cone or Beam limiting device): It is made up of transparent polycarbonate or lead-coated polycarbonate which ensures (i) the exact distance between focal spot and skin (ii) dimension, direction and positioning of x-ray beam (iii) the realisation of different radiographic technique (biting and parallel technique)
Brand | ACTEON |
---|---|
Model Name/Number | X-mind DC |
Power Consumption | 230 V |
Focal Spot | 0.7 mm |
Voltage | 60-70 kV |
Inherent Filtration | 0.8 mm Al |
Leaking Radiation | 0.25 mGy/hour |
Exposure Time | 0.02 - 3.2 seconds |
Warranty Summary
Warranty of the product is limited to manufacturing defects only.
Warranty Service Type
By company person
Covered In Warranty
X-Ray Head
Not Covered In Warranty
Warranty does not cover any external accessories damage caused to the product due to improper installation by customer, incase of water, fire, dropping or excessive shock, any damage caused due to tampering of the product by an unauthorized agent, liability for loss of data, recorded images or business opportunity loss.
Domestic Warranty
2 Years
Installation
Free installation in Bangalore